C-COAT 100M Masonry NF Plaster

PRODUCT DESCRIPTION

C-COAT 100M – MASONRY NF PLASTER is a water-based thermal insulating barrier, energy preservation plaster developed for to block heat transfer over nonferrous (masonry) types of surfaces within the recommended application temperatures.

C-COAT 100M consists of high-temperature acrylic binders with solid and vacuum micro-spheres. The combination of the glass/ceramic distribution and sizes of micro-spheres is designed, to fill as much of the volume as possible, results in C-COAT 100M exceptional insulating properties. Material is resistant to UV radiation. It contains fungus and mould inhibitors.

NOTE*: Please pay attention that performance of C-COAT 100M thermal insulating coating material is application, environment and temperature dependent.
* For first-time users, consult us direct or your local distributor before use.

  • Excellent thermal insulating non-flammable material.
  • Providing significant energy savings.
  • Cost effective, with long-term savings and short payback.
  • Reduces cooling energy costs.
  • Non-toxic, water-based, low VOC, UV resistant.
  • Reduces or eliminates CUI.
  • Mould, surface bacteria and moss resistant.
  • Excellent resistance to dirt retention.
  • Moisture resistant.
  • Breathable (will not function as a vapour barrier).
  • Easy to apply in difficult areas.
  • Applied with brush or roller or airless paint sprayer.
  • Space saving.
  • Paintable with High Temperature water-based topcoats.
  • Easy cleanup.
  • 5 Years* Manufacturer’s Warranty.

TDS

Technical Data Sheets

TDS for T100M

C-COAT 100M – MASONRY NF PLASTER

DESIGNATION CHARACTERISTIC
Packaging Tight sealed plastic bucket
Packaging volume 20 Lit – Standard pail and 5, 10 Lit optional
Colour “C-COAT WHITE” C(0.0.1); D(0.0.1); L(0.0.6)
Formula base Water-based styrene acrylic dispersion
VOC (volatile organic compounds) 3.0 [g/Lit] (Test Method DMS 0033: 2016)
13.0 [g/Lit] Green Building Council AU
Weight 0.56 [kg/Lit] (±3%)
Elongation Above 50% (ASTM412)
Hardness Shore “A” 55 – A/15:64 (ISO868:2003)
Density 290 kg/m3 (ASTM D 1622-98)
Elasticity of the coated film (Band Test) 5.0 (DSTU ISO 1519)
Thermal conductivity (*see our published modelling) Tested: 0.035 [W/mK] (ASTM C 518-10)
Equivalent*: 0.00037 – 0.0012 [W/mK]
R Value equivalent* 0.5 mm equiv. to R.3 (130mm of glass-wool)
1.0 mm equiv. to R.4 (200mm of glass-wool)
Solar reflective index 104.85% (ASTM E 1980:11)
Vapour permeability <2% (DSTU EN 1062-3:2015)
Pull of strength (adhesion) concrete 1.09 [N/mm] (DSTU ISO 4624)
Pull of strength (adhesion) steel 0.81 [N/mm] (DSTU ISO 4624)
Pull of strength (adhesion) brick 1.33 [N/mm] (DSTU ISO 4624)
Combustibility Non-Flammable
AU – AS1530.3 (Spread of Flame – 0, Smoke – 4)
EU – PN-EN 13823, ISO 11925 – (B-s1, d-0)
Application temperature* +7°С to +60°С (for higher temp’s use priming)
Operating temperatures* From -40°С to +100°С
(Peak @+120°С for not more than 1 hours)
Drying time at + 20°C in humidity ≤80% 60 min to touch
Storage and transportation temperature +5°С to +45°С
Resistance to temperatures -40°C to +100°C No changes after full cure
Application method Airless sprayer, brush, roller
Abrasion resistance High
Shelf-life of the material Up to 24 months from the DOM
Service life Thermal properties >10 years.
Physical properties >20 years
Protecting surface from corrosion formation 500 hours ASTM B117-02
equal to 10 years’ life expectancy
Top coating Water based solutions – Please contact supplier
Theoretical coverage (add waste and over-spray about 5-10%) 0.5mm DFT thickness = 0.7Lit/m2
1.0mm DFT thickness = 1.4Lit/m2
Recommended thickness per layer 0.5 – 1.0mm DFT
0.7 – 1.4mm WFT
(vertical surface – horizontal surface

SDS

Safety Data Sheets

SDS for 100M

C-COAT 100M – Masonry NF Plaster

Chemical nature Based on ceramic micro-spheres and acrylic polymer.
Trade Name C-COAT 100M – Masonry NF Plaster
Product Use TIC – Thermal Insulating Coating
Creation Date October 2016
This version issued February 2023 and is valid for 5 years from this date.
Poisons Information Centre: Phone 13 1126 from anywhere in Australia

Applications

Applications

Energy Savings at homes and commercial properties Roofing and facade protection
A/C energy reduction
Indoor comfort improvements
Maintenance cost reduction
Energy Savings at Industrial Plants Power plants
Chemical plants
Food processing plants
Oil and gas plants
Marine and offshore oil platforms
Automotive Industry Trucks and buses heat-blocking systems
Transport and storage containers
Defence and Space IR and heat-blocking systems
Fire and Smoke Protection Surface fire protection as NF modification
OHSA and Insurance Industry Hot surfaces protection with “Safe to Touch” effect
Sound Dampening Reduction in sound at particular frequencies

Want To Learn More About C-Coat?